Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 420V 11.8x17.0mm DIA
2063-42-ALF
Bourns
1:
£10.21
54 In Stock
Mouser Part No
652-2063-42-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 420V 11.8x17.0mm DIA
54 In Stock
1
£10.21
5
£9.93
10
£9.47
50
£7.29
105
£5.87
Buy
Min.: 1
Mult.: 1
Details
2063
100 kA
420 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 600V 11.8x12.0mm DIA
2061-60-ALF
Bourns
1:
£9.40
176 In Stock
Mouser Part No
652-2061-60-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 600V 11.8x12.0mm DIA
176 In Stock
1
£9.40
5
£9.11
10
£6.98
50
£6.61
180
£5.09
Buy
Min.: 1
Mult.: 1
Details
2061
60 kA
600 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 350V 11.8x17.0mm DIA
2063-35-ALF
Bourns
1:
£10.21
92 Expected 10/04/2026
Mouser Part No
652-2063-35-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 350V 11.8x17.0mm DIA
92 Expected 10/04/2026
1
£10.21
5
£6.49
10
£5.99
50
£5.27
105
£5.17
Buy
Min.: 1
Mult.: 1
Details
2063
100 kA
350 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 230V 11.8x12.0mm DIA
2061-23-ALF
Bourns
180:
£5.08
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-23-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 230V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
180
£5.08
540
£5.01
1,080
£4.97
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
230 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 250V 11.8x12.0mm DIA
2061-25-ALF
Bourns
180:
£5.40
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-25-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 250V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
250 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 300V 11.8x12.0mm DIA
2061-30-ALF
Bourns
180:
£5.52
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-30-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 300V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
300 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 350V 11.8x12.0mm DIA
2061-35-ALF
Bourns
180:
£5.12
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-35-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 350V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
350 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 420V 11.8x12.0mm DIA
2061-42-ALF
Bourns
180:
£5.09
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-42-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 420V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
420 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 470V 11.8x12.0mm DIA
2061-47-ALF
Bourns
180:
£5.68
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-47-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 470V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
470 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 700V 11.8x12.0mm DIA
2061-70-ALF
Bourns
180:
£5.01
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-70-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 700V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
700 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 800V 11.8x12.0mm DIA
2061-80-ALF
Bourns
180:
£5.52
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2061-80-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 800V 11.8x12.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 180
Mult.: 180
Details
2061
60 kA
800 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
12 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 230V 11.8x17.0mm DIA
2063-23-ALF
Bourns
1:
£10.09
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-23-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 230V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
1
£10.09
5
£8.38
10
£7.73
50
£6.36
105
View
105
£5.50
210
£5.17
Buy
Min.: 1
Mult.: 1
Details
2063
100 kA
230 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 250V 11.8x17.0mm DIA
2063-25-ALF
Bourns
1:
£10.21
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-25-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 250V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
1
£10.21
5
£9.93
10
£7.79
50
£5.95
105
View
105
£5.63
210
£5.56
Buy
Min.: 1
Mult.: 1
Details
2063
100 kA
250 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 470V 11.8x17.0mm DIA
2063-47-ALF
Bourns
105:
£5.87
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-47-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 470V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
Buy
Min.: 105
Mult.: 105
Details
2063
100 kA
470 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 600V 11.8x17.0mm DIA
2063-60-ALF
Bourns
105:
£5.40
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-60-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 600V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
105
£5.40
210
£5.37
525
£5.32
1,050
£5.31
Buy
Min.: 105
Mult.: 105
Details
2063
100 kA
600 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 700V 11.8x17.0mm DIA
2063-70-ALF
Bourns
105:
£5.88
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-70-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 700V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
105
£5.88
210
£5.87
1,050
£5.85
2,520
Quote
2,520
Quote
Buy
Min.: 105
Mult.: 105
Details
2063
100 kA
700 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 800V 11.8x17.0mm DIA
2063-80-ALF
Bourns
105:
£5.66
Non-Stocked Lead-Time 13 Weeks
Mouser Part No
652-2063-80-ALF
Bourns
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 800V 11.8x17.0mm DIA
Non-Stocked Lead-Time 13 Weeks
105
£5.66
210
£5.60
525
£5.56
1,050
£5.55
Buy
Min.: 105
Mult.: 105
Details
2063
100 kA
800 V
2 Electrode
SMD/SMT
Failsafe Not Protected
11.8 mm
17 mm
- 30 C
+ 85 C
Tray