FN 3287/3288 EMC/RFI Filters

TE Connectivity / Schaffner FN 3287/3288 EMC/RFI Filters are based on an innovative filter topology with state-of-the-art EMI attenuation. These filters ensure compliance with Class C2 or C1. The FN 3287/3288 filters come in a slim book-style shape that saves space and allows for installation next to inverters, converters, or motor drives. These TE Connectivity / Schaffner filters act as solid safety connector blocks and are available in HVIT, IT, and low-leakage current versions. The FN 3287 filters offer standard attenuation performance, while the FN 3288 filters provide high attenuation performance. Typical applications include process automation equipment, 3-phase power supplies, low-leakage current requirements, and IT power distribution networks.

Results: 145
Select Image Part # Mfr. Description Datasheet Availability Pricing (GBP) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Filter Type Voltage Rating Current Rating Mounting Style Termination Style Leakage Current Series Operating Frequency
TE Connectivity / Schaffner Power Line Filters FN3287-125-35-C21-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

530 VAC 125 A Terminal Block 420 uA FN3287
TE Connectivity / Schaffner Power Line Filters FN3287-160-40-C33-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 160 A Flange Mount Terminal Block 5.6 mA FN3287 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3287-160-40-C21-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

530 VAC 160 A Terminal Block 420 uA FN3287
TE Connectivity / Schaffner Power Line Filters FN3287-230-40-C26-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

EMC/RFI Filter 530 VAC 230 A Chassis Mount Terminal Block 2.75 mA FN3287 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3287-80-34-C33-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 80 A Chassis Mount Terminal Block 5.6 mA FN3287 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-100-35-C21-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

530 VAC 100 A Terminal Block 400 uA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288-125-35-C26-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 125 A Chassis Mount Terminal Block 2.7 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-125-35-C35-R65 Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 125 A Chassis Mount Terminal Block 7.1 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-125-35-C17-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 125 A Chassis Mount Terminal Block 100 uA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-125-35-C21-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

530 VAC 125 A Terminal Block 400 uA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288-160-40-C26-R65 Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 160 A Chassis Mount Terminal Block 2.7 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-160-40-C35-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 160 A Chassis Mount Terminal Block 7.1 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-160-40-C17-R65 Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 530 VAC 160 A Chassis Mount Terminal Block 100 uA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288-160-40-C21-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

530 VAC 160 A Terminal Block 400 uA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288-230-40-C26-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

EMC/RFI Filter 530 VAC 230 A Chassis Mount Terminal Block 2.7 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HV-100-35-C25-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

760 VAC 100 A Terminal Block 2.6 mA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288HV-125-35-C25-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

760 VAC 125 A Terminal Block 2.6 mA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288HV-125-35-C36-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 760 VAC 125 A Flange Mount Terminal Block 12.4 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HV-160-40-C25-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

760 VAC 160 A Terminal Block 2.6 mA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288HV-160-40-C36-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 760 VAC 160 A Flange Mount Terminal Block 12.4 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HV-230-40-C17-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

EMC/RFI Filter 760 VAC 230 A Chassis Mount Terminal Block 100 uA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HV-230-40-C25-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

EMC/RFI Filter 760 VAC 230 A Chassis Mount Terminal Block 2.6 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HV-80-34-C25-R65 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

760 VAC 80 A Terminal Block 2.6 mA FN3288
TE Connectivity / Schaffner Power Line Filters FN3288HVIT-125-35-C26-R60 Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 760 VAC 125 A Chassis Mount Terminal Block 3.7 mA FN3288 0 Hz to 60 Hz
TE Connectivity / Schaffner Power Line Filters FN3288HVIT-125-35-C44-R60 Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

3-Phase EMC/RFI Filter 760 VAC 125 A Flange Mount Terminal Block 5.9 mA FN3288 0 Hz to 60 Hz