Gas Discharge Tube (GDT) Protectors

HUBER+SUHNER Gas Discharge Tube (GDT) Protectors utilize GDT technology, making them ideal for applications with RF and DC components on the antenna line. These electromagnetic pulse (EMP) protectors make the best of the traditional spark gap protection principle for general applications in electronics and adapt it to RF coaxial line applications. The protectors are generally designed as coaxial feed-through devices for 50Ω or 75Ω systems. They offer DC continuity for remote powering and broadband usage from DC up to 1GHz. HUBER+SUHNER GDT Protectors feature replaceable gas discharge tubes and easy maintenance.

Results: 24
Select Image Part # Mfr. Description Datasheet Availability Pricing (GBP) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Peak Pulse Current DC Sparkover Number of Electrodes Failsafe Protection Y/N Diameter Length Minimum Operating Temperature Maximum Operating Temperature
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 350 V 171In Stock
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 1200 V 7In Stock
Min.: 1
Mult.: 1
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 230 V (for series 3402 platform 3000) 8In Stock
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 470 V with holder 5In Stock
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 9In Stock
Min.: 1
Mult.: 1

HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 230 V 1,475In Stock
1,470Expected 01/05/2026
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 90 V with holder 35In Stock
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 90 V 77In Stock
40Expected 08/06/2026
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 350 V 6In Stock
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 470 V
107Expected 19/06/2026
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 230 V with holder
12Expected 12/05/2026
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 600 V
30Expected 22/06/2026
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 230 V
17Expected 06/05/2026
Min.: 1
Mult.: 1

30 kA 230 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 90 V
6Expected 19/06/2026
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 600 V
12On Order
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 900V Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1

HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 350 V with holder Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 600 V with holder Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 470 V Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 230 V (for series 3409) Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 24 mm 21.6 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 90 V (for series 3409) Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 24 mm 21.6 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 90 V (for series 3402 platform 3000) Non-Stocked Lead-Time 10 Weeks
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 350 V (for series 3402 platform 3000) Non-Stocked Lead-Time 10 Weeks
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 470 V (for series 3402 platform 3000) Non-Stocked Lead-Time 10 Weeks
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 15 mm 19.4 mm